Home
About us
Company profile domestic market global market Enterprise honor
Product Center
anesthetic workstation Ventilator ICU and OT Equipment
technical support
Professional qualification
News Center
news Enterprise dynamics Enterprise advantages
Talent recruitment
Social recruitment

Steam Sterilizer-HS150

Suppliers for Life Support System Solutions

i-Or Operation Room Laminar Flow Project

i-CssD Digital Hospital Central Sterile Supply Department

i-Gas Medical Gas Supply System 

i-Pharm Intelligent Pharmacy Dispenser for Out-patient & In-patient Departments

i-Train Hospital Pneumatic Tube Transportation System


BAIX

i-Steam

Pulse Vacuum Steam Sterilizer

HS Series pulse Vacuum Steam Sterilizer & Consumables


i-Steam Pulse Vacuum Steam Sterilizer

Intelligent sterilization


Technical advantage

1 Android System

The equipment features Android operating system, one-touch operation

2 Cloud Services

After connection with network, the equipment can be monitored realtime and operator can do remote control and download sterilization record

3 Fingerprint Access Control

Users can access the operation interface y finger print ID or password. By using finger print ID technology, the equipment get physiological feature record of operators, so it can trace the responsibility of operators.

4 Text message Notification SMS

The equipment operating staff can get the information about running status of machine by text message SMS.(including running information and fault information)

5 Video Training

Users can receive operation training and infection control knowledge, etc. from the machine.

6 Online Service

Provide the latest news in medical field; Launch the latest equipment information; Update the newest industry knowledge; Provide operating manual and maintenance knowledge.

7 Voice Intercom System

BAIX voice intercom System enablesthe real-time communication between clean and sterile are.

8 Excel File Export

Sterilization data can be exported as excel file so that the record is available for all staff.


Smart Operating System

Main interface

Cloud service interface

Permission verification interface



i-Steam^TM HS150(Single automatic door)


Jacket Pressure Gage

Chamber Pressure Gage

Fingerprint Access Control


10-inch LCD Display

Martix Printer


Android Operating System

Cloud Service Fingerprint Access Control

Video Training 

Text Message Notification (SMS)

Features

Solid Stainless structure with annular strengthening ribs, extending life span of equipment to 15 years.

Bottom structure of steam sterilizer guarantees that condensate water can be easily drained.

Effective heat preservation measures are taken to minimize the energy consumption and release burden of room air-conditioning.

Strict welding process guarantees high quality of main body.

Automatic sliding door is saving space and operator friendly. The automatic sliding door is applied with safety protection devices and manual operation devices.

Water-ring vacuum pump to shorten vacuum time and increase efficiency.

10 inch LCD display dynamically shows temperature, pressure and time, as well as other parameters; Door operation, parameters setting and program running can be controlled and monitored on screen and touch panel.


Technical Specifications

Model Chamber Dimensions Capacity Overall Dimensions Net Weight Control Power(AC220V/50Hz/Kw) Operational Power(2-AC380V.50Hz) Maximum Water Consumption(kg/cycle) Wrapped cycle time(kg/cycle)

HS150 460*460*720 0.15 1066*833*1732 350 0.5 23 120 40-50





i-Steam^TM HS150(double automatic door)


Jacket Pressure Gage

Chamber Pressure Gage

Fingerprint Access Control

Voice Intercom System

10-inch LCD Display

Back Door Touch Panel

Steam Generator Pressure Gage

Matrix Printer

Synchronized Double-screen

Voice Intercom System

Android Operating System

Cloud Service 

Fingerprint Access Control

Video Training 

Text Message Notification (SMS)

Voice Intercom system

Synchronized Double-Screen


Features

Solid Stainless structure with annular strengthening ribs, extending life span of equipment to 15 years.

Bottom structure of steam sterilizer guarantees that condensate water can be easily drained.

Effective heat preservation measures are taken to minimize the energy consumption and release burden of room air-conditioning.

Strict welding process guarantees high quality of main body.

Automatic sliding door is saving space and operator friendly. The automatic sliding door is applied with safety protection devices and manual operation devices.

Water-ring vacuum pump to shorten vacuum time and increase efficiency.

10 inch LCD display dynamically shows temperature, pressure and time, as well as other parameters; Door operation, parameters setting and program running can be controlled and monitored on screen and touch panel.


Technical Specifications

Model Chamber Dimensions Capacity Overall Dimensions Net Weight Control Power(AC220V/50Hz/Kw) Operational Power(2-AC380V.50Hz) Maximum Water Consumption(kg/cycle) Wrapped cycle time(kg/cycle)

HS150(D) 460*460*720 0.15 1066*833*1732 400 0.5 23 120 40-50




i-Steam^TM HS-150(Manual Door)

Features

High Sterilization Capacity

Built-in vacuum pump; multi-times pulse vacuum, and it can reach -0.090MPa; with the 0.22 µ m bacteria air filter, the air which enter the chamber is sterile, in case of recontamination.

Humanized Control System

With chamber pressure gauge, the real-time monitoring of pressure can be realized; large size touch screen and easy operation; multi sets of programme to satisfy different requirements; buzzer reminder after cycle finish rotating door for easy operation.

Professional Manufacturing Technique

Electrolytic polishing for chamber, smooth surface; rust-proof and anti-corrosion strict welding process guarantee the main body quality.


Technical Parameters

Model Capacity(L) Overall Dimension(D*W*H)mm Power Supply(V/Hz) Power(kw)

HS150 150 1130*755*1724 380/50 11/0


i-Steam^TM Consumables

Steam Sterilization Chemical Indicator Card

Used for pressure and steam sterilization monitoring and placed inside the package. It is composed of card with printed words, standard color block and indicator color block. The ink on indicator color block reflects temperature, lasting time of temperature and level of steam saturation, so it can indicate whether the sterilization condition is approved.

2 type available: 

1. Used for sterilization condition of 132℃, 3.5,min.

2. Used for sterilization condition of 121℃, 20min.

Steam Sterilization Biological Indicator

Composed of filter paper with bacterial spore, ampoule bottle with tryptone soy broth and bromocresol purple liquid, bacteria-resisting membrance and plastic bottle.

Bacteria strain: Bacillus stearothermophilus ATCC7953;

Bacteria count: 1*106-5*106 cfu/piece

The label on bottle is printed with special indicator ink and the color change is easily identified.

After 48 hours, the sterilization result can be judged.


B-D Vacuum-Testing Paper Pack

B-D vacuum-testing paper is composed of paper with air permeability and heat-sensitive dye and is used for testing remaining cold air in the process of sterilization. The color will change from light yellow to dark brown or block if no air left in chamber, and the temperature reach 132-134℃, lasting 3.5-4min. if the conditions fail to reach certain value or there is air leakage, the color will remain light yellow or change unevenly.


B-D Test Bag

In compliance with standards of ISO11140 and GB18282

The picture on B-D is easy for reading.

It reflects functions of sterilizer precisely and the result is stable and reliable.

It’s easy for file management and enhance the sterilization quality control system.

i-Steam^TM Consumables

Steam Sterilization Chemical Indicator Label

Composed of heat-sensitive pigment, which will change from yellow to dark brown or black after the temperature, humidity and time reach certain degree. If color changes unevenly, it indicates that the package is not sterilized properly. 

This indicator label is used for sealing and operators can write down record notes.


Steam Sterilization Chemical Indicator Tape

Composed of heat-sensitive pigment, which will change from white to dark brown or black after the temperature, humidity and time reach certain degree. If color changes unevenly, it indicates that this package failed sterilization. 

This indicator label is used fro sealing and operators can write down record notes.


Steam Sterilization Paper Roll

Medical grade paper

Printed with steam indicator ink

Available width from 75mm to 300mm


Steam Sterilization Gusseted Paper Roll

Medical grade paper

Printed with steam indicator ink

Available width from 75mm to 300mm

Plastic side gusseted to provide larger capacity of bags